The qubits are at millikelvin. The control system is in the room.

Superconducting qubits run inside dilution refrigerators, but the microwave control racks, readout electronics and cryoplant sit in room air. Temperature swings in that equipment cause timing jitter and amplitude drift, pulse-tube vibration travels through the floor and frame, and RF and magnetic interference reach the wiring. The room around the refrigerator decides how long a calibration holds.

What drifts, and what Praecis does about it

ProblemEffect on the systemPraecis response
Temperature drift in control and readout electronicsTiming jitter and amplitude drift in control signalsATCU holds ±0.005 °C around the electronics
Pulse-tube and cryoplant vibrationNoise coupled into the refrigerator and wiringIsolation designed with the cryogenic plant running
RF interferenceNoise on control and readout linesGasketed conductive shell; filtered, waveguide feedthroughs
Magnetic field changesFlux noise and qubit frequency shiftsPassive shielding, active field cancellation, or both
Condensation at cold interfacesMoisture on connectors and linesHumidity control designed around each cold interface

Consistent over long runs

Calibration and computation cycles run for hours. Praecis holds the room-temperature side steady across them, and the ATCU logs conditions continuously so drift in results can be checked against the environment.

Measured performance

In a 28-hour test, room temperature varied 1.19 °C while the critical point held within 0.005 °C.