The qubits are in vacuum. The lasers are not.
In trapped-ion and neutral-atom systems, the qubits sit in an ultra-high-vacuum chamber, but every operation on them travels through open air. Laser beams for cooling, gates, tweezers and readout pass through room-temperature optics on the optical table. Outside the vacuum, the environment sets the limit on gate fidelity and how long a calibration holds.
What drifts, and what Praecis does about it
| Problem | Effect on the system | Praecis response |
|---|---|---|
| Temperature drift | Optical table and mounts expand; beam pointing and laser frequency drift | ATCU holds ±0.005 °C at the critical point |
| Air movement and density changes | Beam-pointing jitter and phase noise along the beam paths | Low-velocity, engineered air delivery that avoids beam paths |
| Magnetic field fluctuations | Qubit frequencies shift; coherence drops | Passive high-permeability shielding, active field cancellation, or both |
| Vibration and acoustic noise | Optics and trap move relative to the beams | Acoustic construction; enclosure and ATCU decoupled from the table |
| Humidity and contamination | Optics and coatings degrade, especially UV optics | RH setpoint control, HEPA or ULPA filtration, positive pressure |
| High-power and UV lasers | Personnel hazard during alignment and service | Class 1 laser enclosure with interlocks and rated viewing windows |
Built around your optical table
Praecis enclosures are free-standing and do not rest on the table. The enclosure, ATCU and airflow are designed around your table size, beam layout and access needs, with sealed fiber and cable feedthroughs that keep shielding and laser containment intact.
Measured performance
In a 28-hour test, room temperature varied 1.19 °C while the critical point held within 0.005 °C.
Talk to us
Send us your table size, setpoint and stability target, and room conditions. Request a consultation or call Susan Thompson, 603-387-9680.